Test the configuration

Once all cameras are adjusted, run a Configuration Test to verify the WIB™ Unit configuration and connectivity before or during production. To ensure you are starting with a clean session and the correct configuration, close and reopen the session and the WIB™ Capture Program before beginning.

Note: Camera assignments and available photo buttons are determined by the capture workflow, which is an administrator configuration. These settings should not change once configured. If buttons or photo types are missing, contact your administrator to verify the workflow configuration.

Run a test box through the full capture sequence and verify each of the following:

  1. Camera assignments — Confirm each camera is assigned to the correct view (Standard, Stadium, Array). Refer to Camera Channels - Assign Cameras if a camera is not assigned to the expected view. If the workflow requires the stadium document camera to capture a standard view (for Large Letter Boxes 24" x 12" x 10" or Large/Legal Boxes 24" x 15" x 10"), verify the stadium camera is configured accordingly.
  2. Image quality — After capturing each photo type, review images in the Image Strip to confirm they are in focus and meet the capture threshold defined in the Service Level Agreement (e.g., 100% file label visibility). Use the Preview Pop-Out Window for a full-scale view while capturing stadium photos. Refer to 09 - Preview and Review Images from Image Strip.
  3. Retake if needed — If an image does not meet requirements, delete it from the Image Strip and retake. Manifest, Standard, Stadium, and File Level photos can be deleted. Refer to 10 - Retake an Image.
  4. Close the test session — Select Stop in the Current Box section of the Message Center to close the session. Confirm closing when prompted. Refer to 12 - Close a Session.
  5. Confirm transfer — In the System Status section of the Message Center, verify that Content to Upload reads 0 before proceeding. Refer to 13 - Confirm Transfer.
  6. Confirm upload in WIB™ Review — Log in to the WIB™ Portal and navigate to the test session to confirm all images transferred and are visible. Refer to 14 - Review Images on WIB Review.

If any step fails, refer to the Troubleshooting articles for guidance.

    • Related Articles

    • Camera Settings/Configuration Buttons

      Save Save allows the user to save custom settings. This gives the user the ability to load a saved camera configuration that is different from the default settings. Reset Default Reset Default allows the user to quickly reset the settings to the ...
    • 08 - Stadium Camera Photos

      Previous Article: 07 - How to Use Stadium Ramp Photos the Stadium Camera Captures The Stadium Document Camera takes the following photos: Document, File, Stadium, Standard and Manifest. There is a button for each photo type at the bottom of the live ...
    • Camera Settings

      Camera Settings Camera settings include setting the Channel, Resolution, show/hide Focus Controls, and Configuration for each camera. There are two (2) types of cameras: array and document. The three (3) array cameras capture the front, back, left, ...
    • Section 1.1.1.5 Configure Barcode Scanner

      WIB™ Capture integrates with the Wasp WDI4600 barcode scanner. When the scanner is connected and configured correctly, operators can scan a barcode to trigger a new box automatically. If a different barcode scanner is used, the operator must select ...
    • Camera Resolution

      Resolution Image resolution is the number of rows and columns in pixels. The 3284 x 1840 is optimal resolution setting for the cameras, however, the resolution can be changed to decrease file size for photos of less importance i.e., the photo of the ...